SELF-DIAGNOSIS

The Full Automatic Temperature Control (F.A.T.C) module self test feature will detect electrical malfunctions and provide error code for system components with suspected failures.

CONTROL PANEL
SELF-DIAGNOSIS METHOD
HOW TO READ SELF-DIAGNOSTIC CODE
1.

After the display panel flickers three times every 0.5 second, the corresponding error code flickers on the setup temperature display panel every 0.5 second and will show two figures.

2.

If error code is more than two, each code flicker 2 times in sequence.

FAULT CODE DISPLAY
1.

Normal

2.

One error code

3.

More error codes than two

4.

Checking each error code

DTC CHART

If malfunction code is displayed during the DTC check, check the circuit listed for that code in the table below.

DTC code

Detection item

Trouble area

00

Normal

-

11

Open INCAR Sensor circuit

Incar sensor

Harness or connector between incar sensor and A/C control assembly

A/C control assembly

12

Shorted INCAR Sensor circuit

13

Open Ambient sensor circuit

Ambient sensor

Harness or connector between ambient sensor and A/C control assembly

A/C control assembly

14

Shorted Ambient sensor circuit

15

Open water temp. sensor

Water temp. sensor

Harness or connector between water temp. sensor and A/C control assembly

A/C control assembly

16

Shorted water temp. sensor

17

Open evap. sensor

Evap. sensor

Harness or connector between evap. sensor and A/C control assembly

A/C control assembly

18

Shorted evap. sensor

19

Open or shorted temp. door potentiometer

Harness or connector between temp. door potentiometer and A/C control assembly

20

Defective temp. door potentiometer

Temp. door potentiometer

21

Open or shorted mode door potentiometer

Harness or connector between mode door potentiometer and A/C control assembly

22

Defective mode door potentiometer

Mode door potentiometer

23

Open Humidity sensor circuit

Humidity sensor

Harness or connector between humidity sensor and A/C control assembly

A/C control assembly

24

Shorted Humidity sensor circuit

FAIL SAFE FUNCTION

No.

Item

Failure

FAIL SAFE Function

1

IN-CAR temperature sensor

Open/Short

25°C alternate value control

2

Ambient temperature sensor

Open/Short

20°C alternate value control

3

Evaporator sensor

Open/Short

-2°C alternate value control

4

Water temperature sensor

Open/Short

-20°C alternate value control

5

Temperature door potentiometer

Open/Short setup temperature

For 17°C to 24.5°C, set to maximum cooling position.

For 25°C to 32°C, set to maximum heating position.

6

Mode door potentimeter

Open/Short setup mode

Vent mode, at vent mode

Def mode, at except vent mode