Component Location
General Description

The Evaporator sensor is located on the AC/heater boxand it detects the evaporator core temperature. When the core temperature is below the threshold value, the A/C ECU interrupts the compressor relay in order to prevent evaporator freezing.

DTC Description

DTC B1241 sets if the Evaporator Sensor signal is at or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Short circuit in harness.

2.

Faulty Evaporator sensor.

3.

Faulty A/C Control Unit.

Enable Conditions

Ignition ON

Threshold value

Evaporator Sensor signal is at or below 0.1V for 0.3 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification

※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

43.3

20/68

12.1

0/32

27.6

30/86

8.3

10/50

18

40/104

5.8

Diagnostic Circuit Diagram
Яндекс.Метрика