P0653 is set when the voltage in 'Power #1' circuit is above upper limit for more than 0.1 sec. This code is due to the short to battery in sensor power circuit or the voltage problem inside of ECM.
| Item | Detecting Condition | Possible Cause | ||
| DTC Strategy | 
										•
									 Voltage monitoring | 
										•
									 ACV power supply circuit 
										•
									 CAM power supply circuit 
										•
									 APS 1 power supply circuit 
										•
									 BPS power supply circuit 
										•
									 ECM component | ||
| Enable Conditions | 
										•
									 IG KEY "ON" | |||
| Threshold Value | 
										•
									 when the voltage is above the maximum voltage of sensor power supply. | |||
| Diagnostic Time | 
										•
									 100ms | |||
| Fail Safe | Fuel Cut | NO | ||
| EGR Off | NO | |||
| Fuel Limit | YES | |||
| MIL | NO | |||