Monitor GDS data
■ Check Actuation Test
1.

Vehicle Parked & Ignition ON.

2.

Connect GDS and select "Data Analysis" mode.

3.

Select "Air Mix Door Potentiometer-Passenger" parameter on the "Current Data" with GDS

4.

Select "Actuation Test" for "Passenger Air Mix Door - 0% / 50% / 100%.

5.

With performing Actuation test, check that the value of Air Mix Door potentiometer is changed and close to the value of Actuation Test.

Specification : Check that the value of Air Mix Door Potentiometer at current data should be close to the value of the acutation test .

6.

Does the value of current data follow in accordance with the each actuation test ?

▶ Fault is intermittent caused by poor contact in the sensor’s and/or Control module’s connector or was repaired and Control module’s memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

▶ Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to " Wiring Inspection " procedure .