DTC Description

When ECM detects short to ground in the heater control circuit(S1), ECM sets DTC P0031.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Heater check low

1.

Poor connection

2.

Short to ground in control circuit

3.

S1

Enable Conditions

Battery voltage 10.7~16V

Threshold Value

Short to ground

Diagnostic Time

Continuous

MIL ON Condition

3 driving cycle

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor