DTC Description

If ECM detects that the output signal satisfies the threshold values under enable conditions, ECM sets DTC P0130.

( This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Rationality check

1.

Poor connection

2.

Open or short power/ground in signal circuit

3.

S1

General

Enable

Conditions

Dew point end detected

Fuel feed back control active

Battery voltage > 11V

Exhaust Gas temperature = 280℃~800℃

No injector error

No upstream O2 sensor heater error

Case1

Enable

Conditions

S2 sensor voltage > 0.5V

ThresholdValue

S1 sensor voltage : 0.06 ~ 0.4V

DiagnosticTime

25 sec

Case2

Enable

Conditions

S2 sensor voltage < 0.1V

ThresholdValue

S1 sensor voltage : 0.6 ~ 1.08V

DiagnosticTime

10 sec

Case3

Enable

Conditions

Time after dew point end detected > 10s

ThresholdValue

Counter of l ∆usvk > 2V during 0.04 sec

after heater on→off l ≥ 5 times

MIL ON Condition

3 driving cycle

※ ∆usvk : Sum of the signal voltage change value (S1)

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor