DTC Description

PCM sets DTC P0118 if the PCM detects signal voltage higher than the possible range of a properly operating ECTS.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage range check

1.

Short to battery in signal harness

2.

Open in signal or ground circuit

3.

Poor connection or damaged harness

4.

Faulty ECT sensor

Enable Conditions

6V < Battery voltage

IAT >-30℃(-22℉) or IAT <-30℃(-22℉)

Time after start > 60sec.

Threshold Value

ECTS voltage > 4.94V

Diagnostic Time

1sec.

Mil On Condition

2 Drive Cycles