Signal Waveform & Data
1.

IG key ON.

2.

Check sensor data as below.

3.

Data Analysis

Condition

GDS Sensor Data

APS 1

APS 2

IG Key "ON & Engine "OFF"

Output voltages of APS1 and APS2 are in proportion to accelerating.

APS2 output voltage is half of APS1 output voltage.

Release a pedal fully

0.58~0.93V

0.29~0.38

Depress a pedal fully

3.85~4.35V

1.93~2.18V

4.

Is data in accordance with "Data Anaysis"?

▶ Check for poor connection between PCM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to next procedure.