Disassembly
1.

Disconnect the M-terminal (A) on the magnet switchassembly.

2.

After loosening the 2 screws (A), detach the magnetswitch assembly (B).

3.

Loosen the through bolts (A).

4.

Remove the rear bracket (A) and brush holderassembly (B).

5.

Remove the yoke (A).

6.

Remove the, lever plate (A) and packing (B).

7.

Disconnect the armature (A) and lever (B).

8.

Press the stopper (A) using a socket (B).

9.

After removing the stop ring (A) using stopper pliers(B).

10.

Remove the stop ring (B), stopper (A), overrunningclutch (C) and armature (D).

note

Using a suitable pulling tool (A), pull the overrunningclutch stopper(C) over the stop ring (B).

11.

Reassembly is the reverse of disassembly.