Measure terminal - to - terminal resistance of blower resistor.
measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

Disconnect the negative (-) battery terminal.
Disconnect the blower resistor connector (A) and then remove the blower resistor (B) after loosening the mounting screws.

Installation is the reverse order of removal.