Terminal & Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of vehicle Repair" procedure.

▶ Go to "PCSV circuit inspection" procedure.

Power Circuit Inspection
■ Check Open or Short in power circuit
1.

IG KEY "OFF".

2.

Disconnect PCSV connector.

3.

IG KEY "ON" & ENG "OFF"

4.

Measure the voltage between power terminal of PCSV harness connector and chassis ground.

Specification : Approx B+

note
To view Flash content, you need to install the appropriate browser extension
5.

Is the measured voltage within specification ?

▶ Go to "Control circuit inspection" procedure.

▶ Repair Open or Short to ground circuit and then, go to "Verification of Vehicle Repair" procedure.

Control Circuit Inspection
■ Check Short in signal circuit
1.

IG KEY "OFF".

2.

Disconnect PCSV connector.

3.

IG KEY "ON" & ENG "OFF"

4.

Measure the voltage between control terminal of PCSV harness connector and chassis ground.

Specification : Approx 3.5V

note
To view Flash content, you need to install the appropriate browser extension
5.

Is the measured voltage within specification ?

▶ Go to "Component Inspection" procedure.

▶ Repair Open circuit and then, go to "Verification of Vehicle Repair" procedure.