Component Location
General Description

The purge solenoid is a pneumatic device that meters the air and fuel (purge) vapor flow to thepurge port. In a sense, the purge solenoid is comparable to a fuel injector, because the meteredpurge flow follows the same slope and offset characteristics. However, the purge solenoidnormally runs with a duty cycle at a fixed frequency because the opening response is significantly slower than a fuel injector. It would not practical to run the solenoid synchronously with engine events except perhaps at very low RPM. The normal frequencies for the purge solenoid are between 8 and 20 Hz.

DTC Description

If there is Open in PCSV circuit, ECM sets DTC P0444.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Circuit continuity check, open

1.

Poor connection

2.

Open or Short to ground in power circuit

3.

Open in control circuit

4.

PCSV

Enable Conditions

Battery voltage 10.7~16V

Threshold Value

Disconnected

Diagnostic Time

Continuous

MIL ON Condition

3 driving cycle

Specification

Item

Specification

PCSV Coil Resistance (Ω)

16.0 [20 ℃ 68 ℉]

Diagnostic Circuit Diagram