HO2S(S2) is in the rear side of Catalytic Converter to check the proper operation of catalyst. Oxygen density after the catalytic converter has to be within specific range (around 0.5V when there is no acceclation and deceleration.)
If the oxygen density changes in accordance with HO2S(S1), it means the poor performance of catalytic converter.
If there is not any signal activity, ECM sets DTC P0140.
(This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Signal no activity detect | 1. Poor connection 2. Open or short in signal circuit 3. S2 |
General Enable Conditions |
•
Dew point end detected
•
Battery voltage > 11V
•
Exhaust Gas temperature = 350℃~800℃
•
No upstream O2 sensor heater error
•
Oscillation Test not completed
•
Fuel feed back control active
•
time duration for Target lamba = 0.9 (15sec)
•
Lambda feed back control value = 0.95~1.05
•
Rear O2 sensor heater monitoring - completed | |
Threshold Value |
•
Sensor voltage < 0.65V | |
Diagnostic Time |
•
315 sec | |
MIL ON Condition |
•
3 driving cycle |
※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor
If you release the accelerator pedal suddenly after engine running about 4000 rpm, fuel supply will stop for short period and the O2 sensor service data in the Hi-Scan (Pro) will display values 200mV or lower. When you suddenly press on the accelerator pedal down, the voltage will reach 0.6 ~ 1.0 V. When you let the engine idle again, the voltage will fluctuate between 200 mV or lower and 0.6 ~ 1.0 V. In this case, the O2sensor can be determined as good.