The Air Conditioner Control Module sets DTC B1238 when Ambient Temperature sensor signal is at or over 4.9V for 4 seconds.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Monitoring the Voltage | 1. Poor Connection in harness 2. Open in signal circuit 3. Shrot to battery in signal circuit 4. Faulty Ambient Temperature sensor 5. Faulty Air Conditioner Control Module |
Enable Conditions |
•
IG KEY ON | |
Threshold value |
•
Ambient sensor signal is at or over 4.9V for 4 seconds | |
Failsafe |
•
Displayed '--' and A/C control Module regards and controls it as 20℃(68℉) |