Vehicle Parked & Ignition ON.
Connect GDS and select "Data Analysis" mode.
Select "Direction Potention-Driver" parameter on the "Current Data" with GDS.
Select and perform "Actuation Test" Driver Mode Door - Vent / Floor / Defrost in order.
Check that the value of all the parameters are changed when performing the actuation test.
Specification :Vent - About below 10%, Floor : About 50%, Defrost : About 90%.
Does the value of current data follow in accordance with the each actuation test ?
![]() | ▶ Fault is intermittent caused by poor contact in the sensor’s and/or Control module’s connector or was repaired and Control module’s memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. ▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Go to " Wiring Inspection " procedure. |