Monitor GDS Data
■ Check Actuation Test
1.

Vehicle Parked & Ignition ON.

2.

Connect GDS and select "Data Analysis" mode.

3.

Select " Intake Potentiometer " parameter on the "Current Data" with GDS.

4.

Perform "Actuation Test" for " Air Inlet Mode Selection - Reculation /Fresh in order.

5.

With performing Actuation test, check that the value of each position sensors are changing.

Specification : Recirculation : About 90%, Fresh : About 10%.

6.

Does the value of current data follow in accordance with the each actuation test ?

▶ Fault is intermittent caused by poor contact in the sensor’s and/or Control module’s connector or was repaired and Control module’s memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure.

▶ Go to " Wiring Inspection " procedure .

Яндекс.Метрика