Replacement
1.

Discharge refrigerant from refrigeration system.

2.

Replace faulty tube or hose.

caution

Cap the open fittings immediately to keep moisture or dirt out of the system.

3.

Tighten joint of bolt or nut to specified torque.

caution

Connections should not be torque tighter than the specified torque.

Part tightened

N.m

Kgf.m

lbf.ft

Condenser - Discharge hose

7.8~11.7

0.8~1.2

5.7~8.6

Condenser - Liquid tube

Compressor - Discharge hose

18.6~27.4

1.9~2.8

13.7~20.2

Compressor - Suction hose

Expansion valve - Evaporator

7.8~11.7

0.8~1.2

5.7~8.6

4.

Evacuate air in refrigeration system and charge system with refrigerant.

Specified amount : 420 ± 25g(14.8±0.88 oz.)

5.

Inspect for leakage of refrigerant.

Using a gas leak detector, check for leakage of refrigerant.

6.

Inspect A/C operation.

Яндекс.Метрика