Inspection
1.

Ignition "OFF".

2.

Disconnect the intake actuator connector.

3.

Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 4.

4.

Verify that the intake actuator operates to the fresh position when connecting in the reverse.

1. -                 

2. –                  

3. Fresh              

4. Recirculation

5. 5V (Vcc)

6. Feedback Signal

7. Sensor Ground

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the heater & blower unit assembly.

(Refer to HA group - "Heater Unit")

3.

Disconnect the Intake actuator connector (A).

4.

Loosen the mounting screw and then remove the intake actuator (B).

5.

Installation is the reverse order of removal.