FUSIBLE LINK
SPECIFICATIONS

Circuit

Rated Capacity

Circuit

Rated Capacity

Battery

50A

ABS 1

30A

Generator

120A

ABS 2

30A

Power window

30A

Radiator

30A

Condenser

20A

ECM

40A

Ignition

40A

Blower

40A

INSPECTION
1.

Check for a burnt fusible link with an ohmmeter.

2.

If a fusible link burns out, there is a short or some other problem in the circuit. Carefully determine the cause and correct it before replacingthe fusible link.

caution

The fusible link will burn out within 15 seconds if a higher than specified current flows through the circuit.

FUSE BOX
INSPECTION
1.

Be sure there is no play in the fuse holders, and that the fuses are held securely.

2.

Are the fuse capacities for each circuit correct?

3.

Are there any blown fuses?

If a fuse is to be replaced, be sure to use a new fuse of the same capacity. Always determine why the fuse blew first and completely eliminate the problembefore installing a new fuse.

caution

Never use a fuse of higher capacity than specified.