BASIC INSPECTION
Before performing the inspection of APS, make sure that the follwing items :
Bent or broken terminals, harness connector connection, loose wires and damage or crack.
APS NUMBERING ORDER
Connect the ohmmeter the probes to the APS terminal 3 and the terminal 6 and measure the resistance.
Specification
APS 2 : 1.7 ㏀ ±0.8 ㏀ at 20℃(68℉)
Make sure that the resistance value goes down according to the APS pedal depression.
Measure the resistance between the APS terminal 3 and terminal 6.
- If the resistance is out of specification, or if it doesn’t change smoothly, replace the APS
Do not test the APS with the analogue multimeter due to the risk of damage to the internal circuit.