2.0/2.4 I4 Engine | 2.7 V6 Engine | |
Type | Mold coil | Mold coil |
Primary coil resistance | 0.86 ± 0.09 (Ω) | 0.74 ± 10% (Ω) |
Secondary coil resistance | 12.1 ± 1.8 (KΩ) | 13.3 ± 15% (KΩ) |
2.0/2.4 I4 | 2.7 V6 | |
Type | PGR5C-11 | PFR5N-11 |
RN10PYP4 | RC10PYP4 | |
Plug gap | 1.0-1.1 mm (0.039-0.043 in.) |
Gasoline | Diesel | |
Type | Reduction drive (with planetary gear) | Reduction drive (with planetary gear) |
Voltage | 12V | 12V |
Output | 1.2 KW | 2.0 KW |
No-load characteristics | ||
Terminal voltage | 11V | 11.5V |
Amperage | 90A or below | 100A MAX |
Speed | 2,800 RPM | 4,000 RPM |
Number of pinion teeth | 8 | 9 |
Pinion gap | 0.5-2.0 mm (0.0197-0.079 in.) | 0.5-2.0 mm (0.0197-0.079 in.) |
Gasoline | Diesel | |
Type | Battery voltage sensing | Battery voltage sensing |
Rated output | 13.5V / 95A | 12V / 120A |
Voltage regulator type | Electronic built-in type | Electronic built-in type |
Regulator setting voltage | 14.4 ± 0.3 V | 14.7 ± 0.3 V |
Temperature compensated | -10 ± 3 mV/°C | -10 ± 3 mV/°C |
Type | MF68AH | MF 90 AH |
Ampere hours | ||
5HR | 54 AH or more | 72 AH or more |
Cold cranking [at -17.8°C (0°F)] | 600 A or more | 720 AH or more |
Reverse capacity | 110 min. | 160 min. |
Specific gravity [at 25°C (77°F)] | 1.280 ± 0.01 | 1.280 ± 0.01 |
note COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 or greaterat a specified temperature. REVERSE CAPACITY RATING is the amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5 at 26.7°C (80°F). |
Speed control module | |
Operating voltage range | DC 11 - 16V |
Operating temperature | -30 - +75°C (-22 - +167°F) |
Voltage drop between unit and actuator | 0.4V |
Operating speed range | Low speed limit : 40 ± 2 km/h (25 ± 1 mph) |
High speed limit : 160 ± 2 km/h (99 ± 1 mph) | |
Actuator | |
Rated voltage | DC 12V |
Operating temperature | -30 - +90°C (-22 - +194°F) |
Operating consumption | 3A or less (at 12V 20°C) |
Insulating resistance | 1MΩ or less (at 500V megger) |
Cruise main switch | |
Rated voltage | DC 12V |
Operating force | 0.3 - 1.0 kg |
Voltage drop | 0.15 V or less |
Stop lamp switch | |
Rated voltage | DC 12V |
Rated load | |
Stop lamp | 27 x 5W (lamp load) |
Cruise control | 0.1 - 0.5A (relay load) |
Insulating resistance | Min 3 MΩ (by 500V megger) |
Items | Nm | Kg·cm | Ib·ft |
Generator terminal (B+) | 5-7 | 50-70 | 3.6-5.1 |
Starter motor terminal (B+) | 10-12 | 100-120 | 7.3-8.8 |
Battery terminal | 4-6 | 40-60 | 2.9-4.3 |
Spark plug | 20-30 | 200-300 | 15-22 |