Ignition "OFF"
Measure resistance between terminals 1 and 3 of the ECT sensor connector (Component side)
Specification :
Temperature | Resistance(kΩ) |
20℃(68℉) | Approx. 2.31 ~ 2.59 |
40℃(104℉) | Approx. 1.00 ~ 1.30 |
80℃(176℉) | Approx. 0.31 ~ 0.33 |
Is resistance within the specification?
YES
▶ Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure.
NO
▶ Check ECTS for contamination, deterioration, or damage. Substitute with a known-good ECTS and check for proper operation. If the problem is corrected, replace ECTS and then go to "Verification of Vehicle Repair" procedure.