Possible DTC: P1325 (Glow relay) P1329 (Glow indicator lamp)
* CC-CODE
C018 (Line : Short circuit)
Possible causes of trouble :
Short circuit to Bat line, open circuit Fuse defective Contact resistance Glow time control Glow plug indicator lamp |
C019 (Line : Open circuit)
Possible causes of trouble :
Short circuit to GND line Fuse defective Contact resistance Glow time control Glow plug indicator lamp |
Golw plug idicator lamp lights briefly for self test when Ignition switch is turned on.
Activate the lamp by way of actuator diagnosis.
If check lamp does not flash: Check the fuse.
Check glow lamp wiring.
Activate the lamp by way of actuator diagnosis.
If relay is not switched : Check the fuse.
Measure the supply voltage at relay pin. 2 to GND.
Set value : 8 ~ 15V
Check glow lamp wiring.
Measure the supply voltage at relay pin. 3 to GND.
Set value : 8 ~ 15V
Check glow lamp wiring.
If wiring and fuse is OK, replace the glow relay.
After replace the glow relay, perform the test again.