GLOW RELAY AND GLOW LAMP
1.

Possible DTC: P1325 (Glow relay) P1329 (Glow indicator lamp)

* CC-CODE

(1)

C018 (Line : Short circuit)

A.

Possible causes of trouble :

Short circuit to Bat line, open circuit

Fuse defective

Contact resistance

Glow time control

Glow plug indicator lamp

(2)

C019 (Line : Open circuit)

A.

Possible causes of trouble :

Short circuit to GND line

Fuse defective

Contact resistance

Glow time control

Glow plug indicator lamp

note

Golw plug idicator lamp lights briefly for self test when Ignition switch is turned on.

2.

Activate the lamp by way of actuator diagnosis.

If check lamp does not flash: Check the fuse.

Check glow lamp wiring.

3.

Activate the lamp by way of actuator diagnosis.

If relay is not switched : Check the fuse.

Measure the supply voltage at relay pin. 2 to GND.

Set value : 8 ~ 15V

Check glow lamp wiring.

Measure the supply voltage at relay pin. 3 to GND.

Set value : 8 ~ 15V

Check glow lamp wiring.

4.

If wiring and fuse is OK, replace the glow relay.

5.

After replace the glow relay, perform the test again.