Component Inspection

The purpose of measuring ISCA resistance is to find if the open circuit is in the component.

1.

Measure resistance of ISCA battery power circuit between open coil circuit.

2.

Probe(+) : ISCA power circuit NO2.

Probe(-) : ISCA open coil circuit NO3.

a.

Specification: 20℃(68℉) : 16.5~20.5Ω

3.

Does each resistance indicate continuity circuit?

YES

a.

Thoroughly check for loose,bent or corroded terminals at all connectors in circuit

NO

a.

Open circuit ISCA

b.

Repair as necessary and go to "Verification of Vehicle Repair"