The resistence check of ECTS component is for finding whether open circuit is in the component.
Measure resistance of ECTS signal circuit between ground circuit.
Probe(+) : ECTS signal circuit NO3
Probe(-) : ECTS ground circuit NO1.
Specification: 20℃(68℉) : 2.27~2.64㏀ ,80℃(176℉) : 0.30~0.33㏀
Does each resistance indicate continuity circuit?
YES
Go to "ECM Inspection"
NO
Open circuit ECTS .
Repair as necessary and go to "Verification of Vehicle Repair" procedure
The purpose of checking ECM is to determine whether there is any malfunction of ECM .
ECTS connect and Turn ignition switch to ON.
Probe(+) : ECTS harness connector NO4.
Probe(-) : Chassis ground.
Verify IAT voltage to change while raising or lowering simulation voltage with scan tool within 0.5~3.5 V
Specification: If the data is changeable as simulation voltage changes, it’s OK.
Is temperature data changing within specification?
YES
Temporarily install a known good ECTS and check for proper operation.
If problem is corrected, replace ECTS.
NO
ECM internal faulty.
Repair as necessary and go to "Verification of Vehicle Repair"