The Pressure Control Solenoid Valve A ( PCSV A ) converts the electric signals, which are controlled by the TCM, into hyraulic pressure. The PCSV A controls the hydraulic pressure, which is applied to the Clutches and Brakes, to reduce the shift shock during shifting.
The TCM checks the Pressure Control Solenoid Valve signals by monitoring the feedback signals from the solenoid valve drive circuit. If an unexpected signal is monitored, ( For example, high voltage is detected when low voltage is expected, or low voltage is detected when high voltage is expected) the TCM judges that the PCSV A drive circuit is malfunctioning and sets this code.
Item | Detecting Condition & Limp Home | Possible Cause |
DTC Strategy | ● Proper functional response and circuit continuity | ● Check line open and short between PCM C33-2 terminal 39 and A/T solenoid C04 terminal 5 ● Check for PCSV-A faulty ● Check PCM faulty |
Enable Conditions | ● None | |
Threshold Value | ● Solenoid is turned on and circuit is short ● Solenoid is turned off and circuit is open | |
Diagnostic Time | ● More than 0.3sec | |
Fail Safe | ● 3rd HOLD in D RANGE, 2nd HOLD in 2, L RANGE |