IG KEY: OFF
FLUID TEMPERATURE SENSOR C03 Connoctor :Disconnect
Verify that is displayed like under value.
Specification : Refer to under value.
Temperature ℃(℉) | Resistance (㏀) | Temperature ℃(℉) | Resistance (kΩ) |
-40(-40) | 139.5 | 80(176) | 1.08 |
-20(-4) | 47.7 | 100(212) | 0.63 |
0(32) | 18.6 | 120(248) | 0.38 |
20(68) | 8.1 | 140(284) | 0.25 |
40(104) | 3.8 | 160(320) | 0.16 |
60(140) | 1.98 |
Is resistance displayed near the specified value?
YES
Go to Controller Inspection
NO
Replace ATF TEMPERATURE SENSOR.( Sensor is located within A/T )
IG KEY: ON
FLUID TEMPERATURE SENSOR C03 Connoctor :Disconnect
Select Sensor simulation and service data procedure in SCANTOOL
Channel2 Prove(+) :FLUID TEMPERATURE SENSOR output signal C03 Terminal 1
Channel2 Prove(-) : Battery(-).
Change voltage from 1 to 4.
Are FULID TEMPERATURE SENSOR value changed for simulation ?
YES
Verify Verification Veh. Repair
NO
PCM faulty
Repair, verify Verification Veh. Repair