The Transaxle Range Switch sends the shift lever position information to the TCM using a 12V (battery voltage) signal. When the shift lever is in the D (Drive) position the output signal of Tansaxle Range Switch is 12V and in all other positions the voltage is 0V. The TCM judges the shift lever position by reading all signals, for the Transaxle Range Switch, simultaneously.
The TCM sets this code when the Transaxle Range Switch outputs multiple signals for an extended period of time.
Item | Detecting Condition & Limp Home | Possible Cause |
DTC Strategy | ● Rationality circuit continuity | ● Check for short ofINHIBITOR LINE from power supply to other 12v signal ● Check for Inhibitor SW faulty. ● Check for TCU faulty |
Enable Conditions | ● None | |
Threshold Value | ● Multiple input signals are activated | |
Diagnostic Time | ● More than 30sec | |
Fail Safe | ● Recognition as privious signal ● When you can select N RANGE to D RANGE , inputed more than 2 signal ,recognize N RANGE. ● When you can select D RANGE to N RANGE , inputed signal ,recognize D RANGE. |
Range S/W(C33-2) | 6&9/C33-2 | 6&10/C33-2 | 6&12/C33-2 | 6&11/C33-2 | 4&6/C33-2 | 2&6/C33-2 | ||||||
Gear selection | P | Others | R | Others | N | Others | D | Others | 2 | Others | L | Others |
Specification | 0Ω | Infinite | 0Ω | Infinite | 0Ω | Infinite | 0Ω | Infinite | 0Ω | Infinite | 0Ω | Infinite |