DTC NO | DIAGNOSTIC ITEM | |
P0712 | FLUID (OIL) TEMPERATURE SENSOR SYSTEM | Short to ground side |
P0713 | FLUID (OIL) TEMPERATURE SENSOR SYSTEM | Open |
Detection condition | Possible cause | Check item |
● 10 minutes after engine speed>1000 rpm ● 10 minutes after pulse generator B>1000 rpm ● Low temperature side output voltage>4.3 V SYMPTOM ● Shift shock ● Power shift pattern will not be available | Malfunction ● Fluid temperature sensor ● PCM | ● Fluid temperature sensor ● Harness & connector |