CIRCUIT INSPECTION

DTC

B1377 DSAB, open circuit(R = ∞)

B1378 DSAB Resistance too high (R ≥ 6.0Ω)

B1379 DSAB Resistance too low (R ≤ 1.1Ω)

B1382 PSAB Resistance too high (R ≥ 6.0Ω)

B1383 PSAB Resistance too low (R ≤ 1.1Ω)

B1386 PSAB, open circuit (R = ∞)

CIRCUIT DESCRIPTION

DTC Detecting Condition

Trouble Area

Too high or low resistane between SAB high (+) wiring harness and SAB low (-) wiring harness of squib.

SAB malfunction

SRSCM malfunction

SAB squib

SRSCM

Wire harness

WIRING DIAGRAM
INSPECTION PROCEDURE
1.

Preparation

(1)

Disconnect the negative (-) terminal cable from the battery, and wait at least 30 seconds.

(2)

Remove the DAB module.

(3)

Disconnect the connectors of the PAB, left and right side airbags, belt pretensioners and satellite sensors.

(4)

Disconnect the SRSCM connector.

warning

Place the DAB with the front surface facing upward.

2.

Check the SAB resistance.

[PREPARATION]

Release the airbag activation prevention mechanism on the SRSCM side of the airbag squib side. Connect the dummy (0957A-38200) and dummy adapter (0957A-38300) to the SAB connector of the SRSCM connector side.

warning

Before checking the resistance, you have to insert the shorting bar insert plastic that is attached to the diagnosis checker into the SRSCM connector.

[CHECK]

Measure the resistance between the SAB high (+) and the SAB low (-).

1.4Ω ≤ R ≤ 4.7Ω

3.

Check the SAB squib.

A.

Turn the ignition switch to LOCK.

B.

Disconnect the negative (-) terminal cable from the battery, and wait for 30 seconds.

C.

Connect the SAB connector.

D.

Connect the negative (-) terminal cable to the battery, and wait for 30 seconds.

A.

Turn the ignition switch to ON, and wait for at least 30 seconds.

B.

Clear the malfunction code stored in the memory with the Hi-Scan Pro.

C.

Turn the ignition switch to LOCK, and wait for 30 seconds.

D.

Turn the ignition switch to ON, and wait for 30 seconds.

E.

Using Hi-Scan Pro, check the DTC.

There is no DTC.

[HINT]

Codes other than these may be output at this time, but they are not relevant to this procedure.