p

DTC

P0182

Fuel temp. sensor A circuit low input

P0183

Fuel temp. sensor A circuit high input

DESCRIPTION

The fuel temperature sensor (FTS, A) is located in the fuel-Inlet line to measure the fuel temperature. The FTS uses a thermistor whose resistance changes with the temperature. The electrical resistance of the FTS decreases as the fuel temperature increases, and increases as the fuel temperature decreases.The 5 V power source in the ECM is supplied to the FTS via a resistor in the ECM. That is, the resistor in the ECM and the thermistor in the FTS are connected in series. When the resistance value of the thermistor in FTS changes according to the fuel temperature, the signal voltage also changes. This information of fuel temperature is used in correcting fuel quantity.

DTC DETECTING CONDITION

DTC No

Detecting Condition & Limp Home

Suspect area

P0182

P0183

Detecting Condition

P0182: The output signal voltage < 0.15V

P0183: The output signal voltage > 4.97V

Enable Condition

Ignition switch : ON

Limp Home

Default value: 90°C

Fuel quantity limitation

- Open or short in FTS circuit

- FTS

- ECM

SPECIFICATIONS

FTS

Normal Parameter

Temperature

20°C

40°C

60°C

Resistance

2.27 ~ 2.73kΩ

1.06 ~ 1.28kΩ

0.54 ~ 0.65kΩ

SCHEMATIC DIAGRAM
SIGNAL WAVEFORM
INSPECTION PROCEDURES

Proceed with ECM problem procedure.