DIAGNOSTIC ITEM
P0750

DTC NO

DIAGNOSTIC ITEM

P0750

SHIFT CONTROL SOLENOID VALVE A

- Open -, - Short circuit -

DESCRIPTION

Control fluid pressure that is acting on the shift control valve (SCV) through ON/OFF signals from the PCM to control shifting.

TROUBLESHOOTING FLOW

Detection condition

Possible cause

Check item

IG S/W "ON" or start release

PCM senses an open/short in the SCSV-A

Malfunction of PG-A

Malfunction of connector

Malfunction of PCM

Open/short in SCSV-A circuit

Malfunction of SCSV-A

SYMPTOM

Automatic transaxle will hold 3rd gear when code P0750 is generated.

CIRCUIT DIAGRAM
TROUBLESHOOTING FLOW