INSPECTION
CHECK VALVE OPERATION CHECK

When checking the check valve, keep the check valve fit in the vacuum hose.

1.

Remove the vacuum hose.

note

The check valve is press-fitted inside the vacuum hose at the position of the marking.

2.

Check the operation of the check valve by using a vacuum pump.

Vacuum pump connection

Accept/Reject criteria

Connection at the brake booster side (A)

A negative pressure (vacuum) is created and held

Connection at the brake booster side (B)

A negative pressure (vacuum) is not created

caution

If the check valve is defective, replace it if an assembly unit together with the vacuum hose.