Component Location
General Description

A "hot at all times" from engine control relay is supplied to EPS CM as fail safe relay when EPS CM is "ON". EPS CM uses this as the source in EPS motor and system.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC strategy

● Voltage check

● Sticky fail-safe relay contact part

Enable conditions

● Fail-safe relay "OFF"( just once at IG"ON")

● Voltage between motor terminal < 5V

Threshold value

● Fail-safe relay contact voltage ≥ 5.5 V

Diagnosis time

● 5 sec

Fail safe

● Motor : OFF

● Relay : OFF

● Fail lamp : ON

● Restoration condition : Power "OFF"

Schematic Diagram
Яндекс.Метрика