INSPECTION
TEMPERATURE CONTROL ACTUATOR(PASSENGER’S)
1.

Verify the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the temperture control actuator operates to the cool position when connecting in the reverse.

2.

Check the voltage between terminals 5 and 6.

Specification

Door position

Voltage (5-6)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage :

0.1V or less

Max. heating

4.7 ± 0.15V

High voltage :

4.9V or more

It will feedback current position of actuator to controls.

TEMPERATURE CONTROL ACTUATOR(DRIVER’S)
1.

Verify the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the temperture control actuator operates to the cool position when connecting in the reverse.

2.

Check the voltage between terminals 5 and 6.

Specification

Door position

Voltage (5-6)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage :

0.1V or less

Max. heating

4.7 ± 0.15V

High voltage :

4.9V or more

Яндекс.Метрика