Check resistance of IATS
IG "OFF" and disconnect IATS connector.
Measure resistance between terminal 4 and 5 of IATS connector.(Component Side) after checking out the temperature of IAT with scantool
Specificaton :
Temp. (°C/°F) | Resistance (kΩ) | Temp. (°C/°F) | Resistance (kΩ) |
-40(-40) | 95.95 ~ 105.78 | 20(68) | 3.42 ~ 3.61 |
-20(-4) | 27.4 ~ 29.77 | 40(104) | 1.43 ~ 1.5 |
0(32) | 9.08 ~ 9.72 | 60(140) | 0.66 ~ 0.69 |
10(50) | 5.49 ~ 5.83 | 80(176) | 0.33 ~ 0.34 |
Is the measured resistance within specification ?
YES
▶ Go to "Verification of Vehicle Repair" procedure.
NO
▶ Substitute with a known - good IATS and check for proper operation.
If the problem is corrected, replace IATS and go to "Verification of Vehicle Repair" procedure.