Installation
1.

Place thermostat(B) in coolant inlet pitting(A).

Install the thermostat with the jiggle valve upward.

2.

Install the coolant inlet pitting(A).

Tightening torque

16.66 ~ 19.60Nm (1.7 ~ 2.0kgf.m, 12.30 ~ 14.47lb-ft)

3.

Fill with engine coolant.

4.

Start engine and check for leaks.