Verify that the mode control actuator operates to the defrost position when connecting 12V to the terminal 3 and grounding terminal. Verify that the mode control actuator operates to the vent position when connecting in the reverse.
Check the voltage between terminals 5 and 6.
Door position | Voltage (5-6) | Error detecting |
Vent | 0.3 ± 0.15V | Low voltage : 0.1V or less |
Defrost | 4.7 ± 0.15V | High voltage : 4.9V or more |
* It will feedback current position of actuator to controls.
Disconnect the negative (-) battery terminal.
Remove the driver’s crush pad lower panel. (Refer to BD group)
Disconnect the mode control actuator connector (A) after removing the air duct.
Loosen the mounting screws and then remove the mode control actuator (B).
Installation is the reverse order of removal.