Connect scantool to Data Link Connector(DLC)
Ignition "ON" & Engine "OFF".
Select the "Actuation Test" mode on the scantool.
Inspect opearating status of Front left valve(in) with Actuation Test.
Specification : It’s normal if operating sound is heard.
Does a Front left valve(in) operate normally?
YES
Fault is intermittent caused by faulty valve or was repaired and HECU memory was not cleared. Go to "Verification of Vehicle Repair" procedure.
NO
Go to "Component Inspection" procedure.