IG "OFF" and install a scantool.
Connect probe to MAPS and TPS to check signal waveform by using oscilloscope function.
ENG "ON" and monitor signal waveform during accelleration and decelleration.
Specification : Signal waveform will be displayed as follows.
Pressure(kPa) | Voltage(V) |
20 | 0.79 |
46.66 | 1.84 |
101.32 | 4.0 |
Is the relationship between the MAP and the TPS correct ?
![]() | ▶ Go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Substitute with a known - good MAPS and check for proper operation. If the problem is corrected, replace MAPS and go to "Verification of Vehicle Repair" procedure. |