IG "OFF" and disconnect IATS connector.
Measure resistance between signal and ground terminals of IATS connector after checking out the temperature of IATS with scantool (Component Side)
Temp. (℃) | Resistance (kΩ) | Temp. (℃) | Resistance (kΩ) |
-40 | 95.95 ~ 105.78 | 20 | 3.42 ~ 3.61 |
-20 | 27.4 ~ 29.77 | 40 | 1.43 ~ 1.5 |
0 | 9.08 ~ 9.72 | 60 | 0.66 ~ 0.69 |
20 | 5.49 ~ 5.83 | 80 | 0.33 ~ 0.34 |
Is the measured resistance within specification ?
![]() | ▶ Substitute with a known - good ECM and check for proper operation. If the problem is corrected, replace ECM and go to "Verification of Vehicle Repair" procedure. note There is a memory reset function on scantool that can erase optional parts automaticallydetected and memorized by ECM. Before or after testing ECM on the vehicle, use this function to reuse the ECM on the others |
![]() | ▶ Substitute with a known - good IATS and check for proper operation. If the problem is corrected, replace IATS and go to "Verification of Vehicle Repair" procedure. |