Component Inspection
■ Check IATS resistance
1.

IG "OFF" and disconnect IATS connector.

2.

Measure resistance between signal and ground terminals of IATS connector after checking out the temperature of IATS with scantool. (Component Side)

Specification :

Temp. (℃)

Resistance (kΩ)

Temp. (℃)

Resistance (kΩ)

-40

95.95 ~ 105.78

20

3.42 ~ 3.61

-20

27.4 ~ 29.77

40

1.43 ~ 1.5

0

9.08 ~ 9.72

60

0.66 ~ 0.69

10

5.49 ~ 5.83

80

0.33 ~ 0.34

3.

Is the measured resistance within specification ?

▶ Go to "Verification of Vehicle Repair" procedure.

▶ Substitute with a known - good IATS and check for proper operation. If the problem is corrected, replace IATS and go to "Verification of Vehicle Repair" procedure.