Component Location
General Description

The Intake Air Temperature Sensor (IATS) is installed into the Mass Air Flow Sensor (MAFS). The IATS uses a thermistor whose resistance changes with the temperature. The electrical resistance of the IATS decreases as the temperature increases, and increases as the temperature decreases. The 5 V power source in the ECM is supplied to the IATS via a resistor in the ECM. That is, the resistor in the ECM and the thermistor in the IATS are connected in series. When the resistance value of the thermistor in IATS changes according to the intake air temperature, the signal voltage also changes. Using this signal, the information of the intake air temperature, the ECM corrects basic fuel injection duration and ignition timing.

DTC Description

Checking output signals of IATS under detecting condition, if an ouput signal is intermittently below 0.1V, PCM sets P1112.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

● Monitor the signal of IAT sensor

● Poor connection

● Short to ground in signal circuit

● Faulty IATS

● Faulty PCM

Enable Conditions

Case 1

● Engine running state

● No Vehicle speed sensor fault

● Vehicle speed > 50kph(30mph)

Case 2

● Engine running time >120 sec.

● Time from IG "OFF" to IG "ON" > 360 min.

Threshold value

● Intermittently Intake air temperature sensor’s voltage < 0.1V

Diagnosis Time

● Continuous

MIL On Condition

● DTC only(NO MIL ON)

Specification

Temp. (°C/°F)

Resistance (kΩ)

Temp. (°C/°F)

Resistance (kΩ)

-40(-40)

95.95 ~ 105.78

20(68)

3.42 ~ 3.61

-20(-4)

27.4 ~ 29.77

40(104)

1.43 ~ 1.5

0(32)

9.08 ~ 9.72

60(140)

0.66 ~ 0.69

10(50)

5.49 ~ 5.83

80(176)

0.33 ~ 0.34

Schematic Diagram
note
To view Flash content, you need to install the appropriate browser extension
Signal Waveform