Ignition OFF.
Disconnect ATM solenoid valve connector.
Measure resistance between DC solenoide vale terminal of ATM solenoid valve component and ON/START power.
Specification : 5.1 ± 0.3 Ω( 25℃ )
Is measured resistance within specification?
![]() | ▶ Substitute with a known-good PCM/TCM and check for proper operation.If the problem is corrected, replace PCM/TCM and then go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Exchange with a known-good DC solenoid valve and then go to "Verification of Vehicle Repair" procedure. |