Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the OCV connector.

3.

Measure resistance between the OCV terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: Refer to “Specification”

Removal
[CVVT Oil Control Valve (Intake)]
1.

Turn ignition switch OFF and disconnect the negative (-) battery cable.

2.

Remove the intake manifold (Refer to “Intake And Exhaust System” in EM group).

3.

Disconnect the CVVT oil control valve connector (A).

4.

Remove the mounting bolt (B), and then remove the valve from the engine.

[CVVT Oil Control Valve (Exhaust)]
1.

Turn ignition switch OFF and disconnect the negative (-) battery cable.

2.

Disconnect the CVVT oil control valve connector (A).

3.

Remove the cylinder head cover (Refer to “Cylinder Head Assembly” in EM group).

4.

Remove the mounting bolt (A), and then remove the valve from the engine.

Installation
1.

Installation is reverse of removal.

CVVT oil control valve installation bolt:

9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lbf.ft)

caution

Pay attention to color of valve connector (Component and harness side) when installing. If an OCV is installed on opposite bank, the engine may be damaged.

[Connector Color]

Item

Component

Side

Harness Side

Bank1 (RH)

Grey

Bank 2(LH)

Black

Яндекс.Метрика