Component Location
General Description

It contains a thermistor which measures the temperature of the inside. The signal,decided by the resistance value which changes in accordance with perceived inside temperature, is delivered to heater control unit. According to this signal, the control unit regulates incar temperature to intended value.

DTC Description

Air conditioner Control Module sets DTC B1234 if Incar temperature sensor has been detected over 4.9V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Poor connection in wireharness

2.

Open in signal circuit

3.

Short to battery in signal circuit

4.

Faulty Incar temperature sensor

5.

Faulty Air conditioner Control Module

Enable Conditions

IG KEY ON

Threshold value

Incar temperature sensor has been detected over 4.9V for 4 seconds.

Failsafe

Control with the value of 23℃(73.4℉)

Specification
※ Resistance value of incar temp sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-20/-4

285.6

20/68

37.4

-10/-14

164.6

30/86

24.1

0/32

97.7

40/104

15.9

10/50

59.67

50/122

10.8

Diagnostic Circuit Diagram