The mode control actuator is mounted at the heater control unit. The mode control actuator consists of a motor and a feedback potentiometer. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.
Air conditioner Control Module sets DTC B2409 if Driver Direction actuator has not been moved to the mode,where air condition control module controls, within 10 seconds.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Voltage check | 1. Poor contact in harness 2. Open or short in motor power circuit 3. Faulty Driver Direction actuator 4. Faulty air conditioner control module |
Enable Conditions |
•
IG KEY ON | |
Threshold value |
•
No movement to controlled mode position for 10 seconds. | |
Failsafe |
•
Fixed as current position |
Mode Door Position | Voltage |
VENT | 0.45±0.3V |
BI-LEVEL | 1.63±0.3V |
FLOOR | 2.45±0.3V |
MIX | 3.5±0.3V |
DEF | 4.55±0.3V |