Component Location
General Description

The Evaporator sensor is a negative temperature coefficient thermistor that is mounted at the evaporator core. The A/C ECU uses the evaporator sensor data to control A/C compressor operation in order to prevent evaporator freezing.

DTC Description

Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Short circuit in harness

2.

Faulty Evaporator sensor

3.

Faulty A/C Control Unit

Enable Conditions

IG KEY ON

Threshold value

Evaporator sensor has been detected below 01.V for 4 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification
※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

18

20/68

4.8

0/32

11

30/86

3.3

10/50

7.3

40/104

2.3

Diagnostic Circuit Diagram