Once BCM receives head lamp low switch working signal, it sends the signal to SJB by CAN communition. SJB turns on head lamp low.
This code is set when right head lamp low circuit is shotted to ground for more than 150ms during right head lamp low operating.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Load Mornitoring | 1. Poor connection 2. Short to ground in Right head lamp low circuit 3. Faulty Right head lamp low 4. Faulty SJB |
Enable Conditions |
•
IG KEY ON. | |
Threshold Value |
•
It is abnormal if output voltage is 0V.
•
Right Head Lamp Low Circuit Short To Ground | |
Diagnostic Time |
•
Immediately | |
DTC Erasing Time |
•
DTC is erased immediately after trouble fixed. |