Several control units are applied to electronically controlled vehicles. These units perform each control with informations from various sensors. Thus, sharing signal information from sensors is needed, so CAN communication type whose communication speed is high and insensitive to electrical noise by spark generation is adopted to controlling unit(ECM/PCM, ABS, EPS, FATC, CLUSTER, etc). CAN communication consists of CAN BUS HIGH, CAN BUS LOW and two 120Ω resistances in circuit. In order to operate it's SPAS function, the MDPS unit gets the status of gear-shifting from Cluster in a vehicle with M/T.
If the MDPS ECM/PCM doesn't get some signals from cluster, it sets C1628.
Item | Detecting Condition | Possible cause |
DTC Strategy |
•
Cluster CAN message monitoring | 1. Poor connection 2. Connector disconnected 3. Open or short in the circuit 4. Cluster |
Enable conditions |
•
IG KEY " ON" Or Engine " ON " | |
Threshold value |
•
The messages from cluster was not received within the last 500msec
•
7.5V < IGN voltage< 16.5V | |
Fail Safe |
•
Motor : ON
•
Relay : ON
•